Product code: 100006785
One-component polyurethane sealant Tenalux 131L, for road joints, 600 ml Tenax
Tenalux 131L sealant can be used for sealing joints in vertical and inclined building structures. It is easily applied manually by syringing with special pistols. It cures as a result of a chemical reaction with air moisture. The sealant has excellent adhesion to the main building materials, as well as good strength and deformation qualities after curing. It can be used in residential areas.
Where it is used:
- Sealing of seams of industrial floors
- Sealing of joints and cracks in vertical and inclined building structures
- Sealing of expansion joints with a maximum deformation of ± 25 %
Advantages:
- Complies with EN ISO 11600 type F, class 25HM
- It can be applied by syringing in a wide temperature range
- Excellent thixotropy, does not flow in vertical seams
- Excellent adhesion to concrete, metals, organic coatings, plastics, wood and glass
- Excellent resistance to climatic factors, especially in humid and hot conditions
- High resistance to UV radiation
- Retains elasticity in a wide temperature range
- It can be painted with any water dispersion paints
- Eco–friendly and safe to use - does not contain isocyanates, silicones and solvents
- Does not cause corrosion
- Has no smell
- Practically does not shrink
The device of the deformation seam
To prevent the formation of a third plane of contact of the sealant with the structural elements of the seam, it is always necessary to use anti-adhesive compounds or sealing gaskets, such as, for example, a bundle of foamed polyethylene.
To limit the depth of the sealant layer, achieve the recommended ratio of width and depth of the sealant, as well as to reduce material consumption, it is recommended to select the size of the sealing gasket taking into account the actual width of the seam. It is necessary to follow the recommendations for the optimal width and depth of the seam for this sealant. Applying the sealant with a layer thickness less than the minimum recommended leads to a decrease in the durability of the sealing seam. Exceeding the maximum recommended thickness of the sealant layer causes high internal stresses that contribute to the appearance of cracks. Narrow seams need to be enlarged with special tools to achieve the recommended width and depth. Seams that are too wide, as well as seams with a porous, fragile surface, should be treated with appropriate repair compounds.
Surface preparation
The surface in contact with the sealant must be strong, clean and dry.
The surface of the joint must be cleaned of all contaminants that reduce the adhesive strength of the sealant with the surface - from dust, cement film, cement mortar residues, residues of previously applied sealing material, etc., in winter – from snow, frost, ice. The surfaces are cleaned with metal brushes manually or with an electric tool, then purged with compressed air. Places contaminated with oil or fat must be degreased with appropriate solvents according to local regulations. Fresh concrete foundations must be maintained for at least 28 days to reduce humidity to an acceptable level. To check the quality of the seam, we recommend preparing a test seam on the construction site. If, despite compliance with the recommendations for surface preparation, the adhesion of the sealant to the surface is unsatisfactory, it is necessary to apply special methods for surface preparation. In this case, contact the manufacturer's representative.
Applying the sealant
Before applying the sealant, be sure to study the appropriate safety data sheet and make sure that all the manufacturer's instructions are followed.
Make sure that the ambient temperature at the place of application of the sealant is within the permissible range of application temperatures. The sealant is allowed to be applied only to the seams corresponding to the recommended parameters and prepared according to the above instructions. The sealant is applied to the seam by squeezing with the appropriate syringe (gun). Insert the tube with the sealant into the cylinder of the syringe, cut off the tip of the tube from the tip (nozzle) and close the cylinder. Select and install the tip corresponding to the size of the seam. When applying the sealant, the tip of the syringe is inserted into the sealed seam at an angle of 45 °. Filling of a vertical or inclined seam is performed from top to bottom. Horizontal seams are filled in the direction of the hand that holds the handle of the syringe. Gently and evenly squeeze the sealant into the seam, avoiding the formation of voids and air bubbles, ruptures and inflows. At a low temperature, the sealant may have an increased viscosity. In the case of sealing works at low temperatures, it is recommended to keep packages with sealant in a warm room for at least a day to facilitate the process of squeezing out of the syringe. Immediately after filling the seam, it is necessary to align and seal the applied sealant, as well as give it the desired shape with the appropriate tool (spatula) of the appropriate size and configuration. The tool is wetted in a soapy solution to prevent the sealant from sticking. It is not allowed to directly apply a soap solution to a freshly applied sealant. The tools are cleaned immediately after completion of the work with approved solvents (it is recommended to use acetone or whitespirite). Excess hardened mastic is removed mechanically. The newly applied sealant must be protected from rain for a period of time exceeding the time of formation of the surface film. It is possible to use a polyethylene film, tape or other material, while it is necessary to prevent the adhesion of the protective material to the sealant laid in the seam, as well as to prevent damage to the adjacent decorative coating.
|
General data Appearance |
||
|
|
White or gray thixotropic mass, other colors on request |
|
|
Type of polymer |
Single-component MS Polymer, cold curing under the influence of air moisture |
|
|
Packaging |
It is packed in tubes of laminated plastic with a capacity of 600 ml It is delivered in cardboard boxes, 15 tubes in each |
|
|
Warranty period of storage |
18 months in unopened, complete factory packaging, in dry warehouses at a temperature of no more than 30 °C |
|
|
Sealing properties Formation of a surface film |
||
|
|
≈ 20 minutes at 23 °C and 50 relative humidity % |
|
|
Curing speed |
from 3 to 4 mm/day at 23 °C and relative humidity 50 % |
|
|
Shrinkage |
≤ 1 % |
|
|
Density |
≈ 1.5 kg/liter |
|
|
Elasticity |
≥ 70 % (ISO 7389) |
|
|
Strength characteristics |
GOST 21751-76 |
(ISO 8339) |
|
• conditional tensile strength |
≥ 1.8 MPa |
≥ 1.3 MPa |
|
• elongation at the moment of rupture |
≥ 400 % |
≥ 200 % |
|
• modulus of elasticity at 100% elongation |
from 0.7 to 0.9 MPa |
≥ 0.7 MPa |
|
Shore A Hardness |
≥ 40 (ISO 868) |
|
|
Application temperature range |
from 1 °C to 50 °C |
|
|
Operating temperature range |
from – 50 °C to 70 °C |
|
|
Seam characteristics (for vertical structures) Permissible deformation (from nominal size) |
||
|
|
± 25 % |
|
|
Seam depth |
from 5 to 15 mm |
|
|
Seam width |
from 10 to 30 mm |
|
|
The ratio of the width to the depth of the seam |
2 : 1 |
|
Other products in the category
Sealant one-component acrylic window Profflex A for external use, white, 7 kg
Sealant one-component acrylic window Profflex A for external use, white, 600 ml
Sealant one-component acrylic Tenax Profflex B for internal use, white, 600 ml.
Sealant one-component acrylic Tenax Profflex B for internal use, white, 7 kg